Skip to main content

Confidence Measures for Assessing the HARP Algorithm in Tagged Magnetic Resonance Imaging

  • Conference paper
  • First Online:
Statistical Atlases and Computational Models of the Heart. Imaging and Modelling Challenges (STACOM 2015)

Abstract

Cardiac deformation and changes therein have been linked to pathologies. Both can be extracted in detail from tagged Magnetic Resonance Imaging (tMRI) using harmonic phase (HARP) images. Although point tracking algorithms have shown to have high accuracies on HARP images, these vary with position. Detecting and discarding areas with unreliable results is crucial for use in clinical support systems. This paper assesses the capability of two confidence measures (CMs), based on energy and image structure, for detecting locations with reduced accuracy in motion tracking results. These CMs were tested on a database of simulated tMRI images containing the most common artifacts that may affect tracking accuracy. CM performance is assessed based on its capability for HARP tracking error bounding and compared in terms of significant differences detected using a multi comparison analysis of variance that takes into account the most influential factors on HARP tracking performance. Results showed that the CM based on image structure was better suited to detect unreliable optical flow vectors. In addition, it was shown that CMs can be used to detect optical flow vectors with large errors in order to improve the optical flow obtained with the HARP tracking algorithm.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Notes

  1. 1.

    A set of volunteer sequences and phantom images are available from the 2011 STACOM challenge. For these images a set of feature points is tracked over time.

References

  1. Zerhouni, E.A., Parish, D.M., Rogers, W.J., Yang, A., Shapiro, E.P.: Human heart: tagging with MR imaging–a method for noninvasive assessment of myocardial motion. Radiology 169(1), 59–63 (1988)

    Article  Google Scholar 

  2. Axel, L., Dougherty, L.: MR imaging of motion with spatial modulation of magnetization. Radiology 171(3), 841–845 (1989)

    Article  Google Scholar 

  3. Mirsky, I., Pfeffer, J.M., Pfeffer, M.A., Braunwald, E.: The contractile state as the major determinant in the evolution of left ventricular dysfunction in the spontaneously hypertensive rat. Circ. Res. 53, 767–778 (1983)

    Article  Google Scholar 

  4. Götte, M.J., van Rossum, A.C., Twisk, J.W.R., Kuijer, J.P.A., Marcus, J.M., Visser, C.A.: Quantification of regional contractile function after infarction: strain analysis superior to wall thickening analysis in discriminating infarct from remote myocardium. J. Am. Coll. Cardiol. 37, 808–817 (2001)

    Article  Google Scholar 

  5. Delhaas, T., Kotte, J., van der Toorn, A., Snoep, G., Prinzen, F.W., Arts, T.: Increase in left ventricular torsion-to-shortening ratio in children with valvular aorta stenosis. Magn. Reson. Med. 51, 135–139 (2004)

    Article  Google Scholar 

  6. Osman, N.F., Kerwin, W.S., McVeigh, E.R., Prince, J.L.: Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Mag. Reson. Med. 42(6), 1048–1060 (1999)

    Article  Google Scholar 

  7. Osman, N.F., McVeigh, E.R., Prince, J.L.: Imaging heart motion using harmonic phase MRI. IEEE Trans. Med. Imaging 19(3), 186–202 (2000)

    Article  Google Scholar 

  8. Sampath, S., Derbyshire, J.A., Atalar, E., Osman, N.F., Prince, J.L.: Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence. Mag. Reson. Med. 50(1), 154–163 (2003)

    Article  Google Scholar 

  9. Kraitchman, D.L., Sampath, S., Castillo, E., Derbyshire, J.A., Boston, R.C., Bluemke, D.A., Gerber, B.L., Prince, J.L., Osman, N.F.: Quantitative ischemia detection during cardiac magnetic resonance stress testing by use of fastharp. Circulation 107, 2025–2030 (2003)

    Article  Google Scholar 

  10. Cheney, W., Kincaid, D.: Numerical Mathematics and Computing, 6th edn. Bob Pirtle, USA (2008)

    MATH  Google Scholar 

  11. Waks, E., Prince, J.L., Douglas, A.S.: Cardiac motion simulator for tagged MRI. In: Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA 1996) (1996). 0182

    Google Scholar 

  12. Márquez-Valle, P., Kause, H., Fuster, A., Hernández-Sabaté, A., Florack, L., Gil, D., van Assen, H.C.: Factors affecting optical flow performance in tagging magnetic resonance imaging. In: Camara, O., Mansi, T., Pop, M., Rhode, K., Sermesant, M., Young, A. (eds.) STACOM 2014. LNCS, vol. 8896, pp. 231–238. Springer, Heidelberg (2015)

    Google Scholar 

  13. Márquez-Valle, P., Gil, D., Hernàndez-Sabaté, A.: Evaluation of the capabilities of confidence measures for assessing optical flow quality. In: International Conference on Computer Vision - Workshops (2013)

    Google Scholar 

  14. Fisher, R.: Statistical Methods and Scientific Inference. Oliver and Boyd, Edinburgh (1956)

    MATH  Google Scholar 

  15. Newbold, P., Carlson, W., Thorne, B.: Statistics for Business and Economics. Pearson Education, New York (2007)

    Google Scholar 

  16. Van Assen, H., Florack, L., Simonis, F., Westenberg, J., Strijkers, G.: Cardiac strain and rotation analysis using multi-scale optical flow. In: Wittek, A., Nielsen, P.M.F., Miller, K. (eds.) Computational Biomechanics for Medicine V, pp. 89–100. Springer, Heidelberg (2010)

    Google Scholar 

  17. Márquez-Valle, P., Gil, D., Hernàndez-Sabaté, A.: A complete confidence framework for optical flow. In: Fusiello, A., Murino, V., Cucchiara, R. (eds.) ECCV 2012 Ws/Demos, Part II. LNCS, vol. 7584, pp. 124–133. Springer, Heidelberg (2012)

    Google Scholar 

  18. Arts, T., Hunter, W., Douglas, A., Muijtjens, A., Reneman, R.: Description of the deformation of the left ventricle by a kinematic model. J. Biomech. 25(10), 1119–1127 (1992)

    Article  Google Scholar 

  19. Gutberlet, M., Schwinge, K., Freyhardt, P., et al.: Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging. Eur. Radiol. 15(8), 1586–1597 (2005)

    Article  Google Scholar 

Download references

Acknowledgements

Work supported by Spanish project TIN2012-33116. First author is supported by the Dutch Technology Foundation STW, which is part of the Netherlands Organisation for Scientic Research (NWO), and which is partly funded by the Ministry of Economic Affairs. Third author is supported by the FPI-MICINN BES-2010-031102 program. Last author is a Serra Hunter fellow.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hanne Kause .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this paper

Cite this paper

Kause, H. et al. (2016). Confidence Measures for Assessing the HARP Algorithm in Tagged Magnetic Resonance Imaging. In: Camara, O., Mansi, T., Pop, M., Rhode, K., Sermesant, M., Young, A. (eds) Statistical Atlases and Computational Models of the Heart. Imaging and Modelling Challenges. STACOM 2015. Lecture Notes in Computer Science(), vol 9534. Springer, Cham. https://doi.org/10.1007/978-3-319-28712-6_8

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-28712-6_8

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-28711-9

  • Online ISBN: 978-3-319-28712-6

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics