Skip to main content
Log in

Study of aluminium-exposed fish by scanning proton microprobe analysis

  • Original Papers
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

A scanning proton microprobe was used to study the aluminium distribution in gills of bullhead, pumpkinseed and rainbow trout exposed to aluminium at low pH. In the examined pumpkinseed gills, aluminium was located on the secondary lamellae edges. Aluminium hot spots were observed inside the tissue. The presence of aluminium coincided with elevated phosphorus levels. Element maps recorded in bullhead and rainbow trout failed to demonstrate the presence of aluminium. The technique of scanning transmission ion microscopy was used for sample visualisation as well as monitoring of the possible sample damage induced by particle induced X-ray emission-measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. C. Chassard-Bouchaud, Ch. Galle, E. Lopez-Rabereau,Revue des Sciences de l'Eau 1992,5, 37.

    Google Scholar 

  2. C. Galle, C. Chassard-Bouchaud, J. C. Massabuau, F. Escaig, P. Boumati, M. Bourges, D. Pépin,C.R. Acad. Sci. Paris 1990,311(III), 301.

    Google Scholar 

  3. C. Goossenaerts, R. Van Grieken, W. Jacob, H. Witters, O. VanderborghtInt. J. Environ. Anal. Chem. 1988,34, 227.

    Google Scholar 

  4. L. Karlsson-Norrgren, I. Björklund, O. Ljungberg,L.J. Fish Diseases. 1986,9, 11.

    Google Scholar 

  5. J. H. Youson, C. M. Neville,Can. J. Zool. 1987,65, 647.

    Google Scholar 

  6. S. Eeckhaoudt,PhD Thesis, Department of Chemistry, University of Antwerp, Belgium, 1994.

    Google Scholar 

  7. H. W. Lefevre, R. M. S. Schofield, J. C. Overley, J. D. Mac Donald,Scanning Microsc. 1987,1(3), 879.

    Google Scholar 

  8. R. M. Sealock, D. N. Jamieson, G. J. F. Legge,Nucl. Instrum. Method. 1987,B29, 557.

    Google Scholar 

  9. G. S. Bench, G. L. F. Legge,Nucl. Instrum. Methods. 1989,B40/41, 655.

    Google Scholar 

  10. M. Cholewa, G. J. F. Legge, I. Dierck, R. Van Grieken,Nucl. Instrum. Method. 1991,B54, 109.

    Google Scholar 

  11. M. Cholewa. G. J. F. Legge, S. Eeckhaoudt, R. Van Grieken, K. Jones, In preparation.

  12. G. J. F. Legge, I. Hammond,J. Microsc. 1979,117, 201.

    Google Scholar 

  13. J. H. D. Vangenechten,Water Qual. Bull. 1983,8, 150–169.

    Google Scholar 

  14. S. Eeckhaoudt, J. Landsberg, F. Watt, H. Witters, W. Jacob, R. Van Grieken,Microbeam Analysis,1995,4, 103.

    Google Scholar 

  15. S. Eeckhaoudt, W. Jacob, H. Witters, R. Van Grieken,Eur. J. Morphology 1993,30, 296.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Eeckhaoudt, S., Van Grieken, R.E., Cholewa, M. et al. Study of aluminium-exposed fish by scanning proton microprobe analysis. Mikrochim Acta 122, 17–25 (1996). https://doi.org/10.1007/BF01252401

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01252401

Key words

Navigation